Need your opinion about the heath of an internal HDD
by hifi100 from LinuxQuestions.org on (#5CSMV)
Hi,
I have installed Lubuntu 20.04 on a Samsung internal SSD.
I am also using a Seagate spinning HDD for data only.
I had posted the Smart Test results of the HDD on a different forum & I was adviced to not store any important data on the HDD.
I have stored a lot of data on the HDD & haven't faced any data corruption whatsoever. So I am confused.
Can you please tell me your opinion about the health of this HDD ?
Code:$ sudo smartctl --all /dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-58-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST3160215AS
Serial Number: 6RAAA8P8
Firmware Version: 4.AAB
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Sun Dec 27 17:58:29 2020 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 54) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0
3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 088 088 020 Old_age Always - 12308
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 088 060 030 Pre-fail Always - 724803665
9 Power_On_Hours 0x0032 077 077 000 Old_age Always - 20161
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 088 088 020 Old_age Always - 12457
187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 115
189 High_Fly_Writes 0x003a 090 090 000 Old_age Always - 10
190 Airflow_Temperature_Cel 0x0022 063 050 045 Old_age Always - 37 (Min/Max 23/38)
194 Temperature_Celsius 0x0022 037 050 000 Old_age Always - 37 (0 20 0 0 0)
195 Hardware_ECC_Recovered 0x001a 073 067 000 Old_age Always - 9111615
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 2
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 2
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 121 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 121 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 01 72 5a 0d e0 00 00:08:52.207 READ DMA EXT
35 00 01 71 5a 0d e0 00 00:08:52.207 WRITE DMA EXT
25 00 01 71 5a 0d e0 00 00:08:55.415 READ DMA EXT
25 00 01 72 5a 0d e0 00 00:08:55.415 READ DMA EXT
25 00 01 71 5a 0d e0 00 00:08:55.391 READ DMA EXT
Error 120 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 01 72 5a 0d e0 00 00:08:52.207 READ DMA EXT
25 00 01 71 5a 0d e0 00 00:08:52.207 READ DMA EXT
25 00 01 70 5a 0d e0 00 00:08:52.206 READ DMA EXT
25 00 01 6f 5a 0d e0 00 00:08:52.206 READ DMA EXT
25 00 01 6e 5a 0d e0 00 00:08:52.206 READ DMA EXT
Error 119 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
41 00 01 72 5a 0d e0 00 00:43:33.999 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
41 00 01 71 5a 0d e0 00 00:43:33.991 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
41 00 01 70 5a 0d e0 00 00:43:33.983 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
41 00 01 6f 5a 0d e0 00 00:43:33.983 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
41 00 01 6e 5a 0d e0 00 00:43:33.974 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
Error 118 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
42 00 00 00 5a 0d e0 00 00:43:30.570 READ VERIFY SECTOR(S) EXT
42 00 00 00 59 0d e0 00 00:43:30.595 READ VERIFY SECTOR(S) EXT
42 00 00 00 58 0d e0 00 00:43:30.592 READ VERIFY SECTOR(S) EXT
42 00 00 00 57 0d e0 00 00:43:30.591 READ VERIFY SECTOR(S) EXT
42 00 00 00 56 0d e0 00 00:43:30.589 READ VERIFY SECTOR(S) EXT
Error 117 occurred at disk power-on lifetime: 519 hours (21 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 40 70 5a 0d e0 00 00:02:40.034 READ DMA EXT
25 03 01 00 00 00 e0 00 00:02:40.023 READ DMA EXT
35 03 08 8f dc 94 e0 00 00:02:40.023 WRITE DMA EXT
35 03 10 f7 23 91 e0 00 00:02:40.023 WRITE DMA EXT
25 03 1e 81 71 90 e0 00 00:02:40.023 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 13440 -
# 2 Short offline Completed without error 00% 12632 -
# 3 Short offline Completed without error 00% 11525 -
# 4 Extended offline Completed without error 00% 10486 -
# 5 Short offline Completed without error 00% 3978 -
# 6 Extended offline Aborted by host 90% 3715 -
# 7 Short offline Completed without error 00% 3714 -
# 8 Extended offline Completed: read failure 90% 118 11322720
# 9 Extended offline Completed: read failure 90% 118 11322720
#10 Short offline Completed: read failure 90% 118 11322720
3 of 3 failed self-tests are outdated by newer successful extended offline self-test # 1
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


I have installed Lubuntu 20.04 on a Samsung internal SSD.
I am also using a Seagate spinning HDD for data only.
I had posted the Smart Test results of the HDD on a different forum & I was adviced to not store any important data on the HDD.
I have stored a lot of data on the HDD & haven't faced any data corruption whatsoever. So I am confused.
Can you please tell me your opinion about the health of this HDD ?
Code:$ sudo smartctl --all /dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-58-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST3160215AS
Serial Number: 6RAAA8P8
Firmware Version: 4.AAB
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Sun Dec 27 17:58:29 2020 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 54) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0
3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 088 088 020 Old_age Always - 12308
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 088 060 030 Pre-fail Always - 724803665
9 Power_On_Hours 0x0032 077 077 000 Old_age Always - 20161
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 088 088 020 Old_age Always - 12457
187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 115
189 High_Fly_Writes 0x003a 090 090 000 Old_age Always - 10
190 Airflow_Temperature_Cel 0x0022 063 050 045 Old_age Always - 37 (Min/Max 23/38)
194 Temperature_Celsius 0x0022 037 050 000 Old_age Always - 37 (0 20 0 0 0)
195 Hardware_ECC_Recovered 0x001a 073 067 000 Old_age Always - 9111615
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 2
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 2
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 121 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 121 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 01 72 5a 0d e0 00 00:08:52.207 READ DMA EXT
35 00 01 71 5a 0d e0 00 00:08:52.207 WRITE DMA EXT
25 00 01 71 5a 0d e0 00 00:08:55.415 READ DMA EXT
25 00 01 72 5a 0d e0 00 00:08:55.415 READ DMA EXT
25 00 01 71 5a 0d e0 00 00:08:55.391 READ DMA EXT
Error 120 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 01 72 5a 0d e0 00 00:08:52.207 READ DMA EXT
25 00 01 71 5a 0d e0 00 00:08:52.207 READ DMA EXT
25 00 01 70 5a 0d e0 00 00:08:52.206 READ DMA EXT
25 00 01 6f 5a 0d e0 00 00:08:52.206 READ DMA EXT
25 00 01 6e 5a 0d e0 00 00:08:52.206 READ DMA EXT
Error 119 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
41 00 01 72 5a 0d e0 00 00:43:33.999 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
41 00 01 71 5a 0d e0 00 00:43:33.991 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
41 00 01 70 5a 0d e0 00 00:43:33.983 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
41 00 01 6f 5a 0d e0 00 00:43:33.983 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
41 00 01 6e 5a 0d e0 00 00:43:33.974 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
Error 118 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
42 00 00 00 5a 0d e0 00 00:43:30.570 READ VERIFY SECTOR(S) EXT
42 00 00 00 59 0d e0 00 00:43:30.595 READ VERIFY SECTOR(S) EXT
42 00 00 00 58 0d e0 00 00:43:30.592 READ VERIFY SECTOR(S) EXT
42 00 00 00 57 0d e0 00 00:43:30.591 READ VERIFY SECTOR(S) EXT
42 00 00 00 56 0d e0 00 00:43:30.589 READ VERIFY SECTOR(S) EXT
Error 117 occurred at disk power-on lifetime: 519 hours (21 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 40 70 5a 0d e0 00 00:02:40.034 READ DMA EXT
25 03 01 00 00 00 e0 00 00:02:40.023 READ DMA EXT
35 03 08 8f dc 94 e0 00 00:02:40.023 WRITE DMA EXT
35 03 10 f7 23 91 e0 00 00:02:40.023 WRITE DMA EXT
25 03 1e 81 71 90 e0 00 00:02:40.023 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 13440 -
# 2 Short offline Completed without error 00% 12632 -
# 3 Short offline Completed without error 00% 11525 -
# 4 Extended offline Completed without error 00% 10486 -
# 5 Short offline Completed without error 00% 3978 -
# 6 Extended offline Aborted by host 90% 3715 -
# 7 Short offline Completed without error 00% 3714 -
# 8 Extended offline Completed: read failure 90% 118 11322720
# 9 Extended offline Completed: read failure 90% 118 11322720
#10 Short offline Completed: read failure 90% 118 11322720
3 of 3 failed self-tests are outdated by newer successful extended offline self-test # 1
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.