Underwater Datacenter Will Open For Business This Year
A company called Subsea Cloud is planning to have a commercially available undersea datacenter operating off the coast of the US before the end of 2022, with other deployments planned for the Gulf of Mexico and the North Sea. The Register reports: Subsea, which says it has already deployed its technology with "a friendly government faction," plans to put its first commercial pod into the water before the end of this year near Port Angeles, Washington. The company claims that placing its datacenter modules underwater can reduce power consumption and carbon dioxide emissions by 40 percent, as well as lowering latency by allowing the datacenter to be located closer to metropolitan areas, many of which are located near the coast. However, according to Subsea founder Maxie Reynolds, it can also deploy 1MW of capacity for as much as 90 percent less cost than it takes to get 1MW up and running at a land-based facility. The Port Angeles deployment, known as Jules Verne, will comprise one 20ft pod, which is similar in size and dimensions to a standard 20-foot shipping container (a TEU or Twenty-foot Equivalent Unit). Inside, there is space for about 16 datacenter racks accommodating about 800 servers, according to Subsea. Additional capacity, if and when required, is delivered by adding another pod. The pod-to-shore link in this deployment provides a 100Gbps connection. As it is a commercial deployment, Jules Verne will be open for any prospective clients or partners to come and check it out, virtually or otherwise, according to Reynolds. It will be sited in shallow water, visible from the port, whereas the Njord01 pod in the Gulf of Mexico and the Manannan pod in the North Sea are expected to be deeper, at 700-900ft and 600-700ft respectively. The Subsea pods are kept cool by being immersed in water, which is one reason for the reduced power and CO2 emissions. Inside, the servers are also immersed in a dielectric coolant, which conducts heat but not electricity. However, the Subsea pods are designed to passively disperse the heat, rather than using pumps as is typical in submersion cooling in land-based datacenters. But what happens if something goes wrong, or a customer wants to replace their servers? According to Subsea, customers can schedule periodic maintenance, including server replacement, and the company says that would take 4-16 hours for a team to get to the site, bring up the required pod(s), and replace any equipment.



Read more of this story at Slashdot.